Check of design for asbestos-cement pipes in soil subjected to soil load, traffic and important internal pressures.
Client: N&R Consult AS, for DANIDA of the Danish Ministry for Foreign Affairs
Year: 1993
Bearing capacity check of sewer pipe (plain concrete, eurf(st) 1400 mm) applied to lateral loads from pile foundations supporting wind turbines
Client: Eurorør AS, Vejle
Year: 1995
Verification of German design specifications could be applied to Danish concrete pipes from Eurorør A/S.
Design of new cross section for concrete pipes, EURORØR Ø 300 (unreinforced concrete, ID 300 mm).
Bearing capacity check of sewer pipe (plain concrete, ig-pipe with footing: 1200x2250mm) taken into account the actual degree of compaction of the supporting soil (backfill).
Client: Per Aarsleff A/S
Year: 1997
Safety evaluation for existing pile foundation for pipes subjected to new loading from land reclamation. Elastic-, plastic- and shake-down analyses.
Client: Gentofte Municipality
Check of design for double spirally coiled reinforced concrete mini tunnel in heavy overconsolidated soil subjected to soil load and heavy traffic loads. ULS and SLS analyses.